DAIRY
- BEVERAGE COOLER
Panels:
- -
8' Standard Height
- -
4" Thick polystyrene insulated cam lock wall panels
built to NSF standards
- -
White embossed metal in/out/aluminum/ galvanized
- -
UL approved door panel assembly
*
Includes: interior light prewired to exterior switch, digital
thermometer and lockable handle
Choice
of remote refrigeration system:
- Indoor:
Condensing unit with matching low silhouette evaporator
coil and temperature operated control package. R-404 Refrigerant
and required tubing by others.
- Outdoor:
(See Outdoor Model) Condensing unit with matching low silhouette
evaporated coil, pumpdown control package and weatherhood.
R-404 Refrigerant and required tubing by others.
|
|
Click on Model# for product RFQ form
SIZE
O.D. FT
|
BTU/HR
REQUIRED
|
REMOTE
REFRIGERATION SYSTEM
|
CONTROL
PANEL
MODEL #
|
COIL
MODEL #
|
INDOOR
UNIT
|
OUTDOOR
UNIT
|
AIR-COOLED
|
WATER-COOLED
|
AIR-COOLED
|
208-220/3/60
|
MCQUAY
|
8
x 8 |
6600 |
A1OH1 |
W8H1 |
PA10H1 |
2T-FT
|
RLC072C
|
8
x 10 |
7800 |
A10H1 |
W10H1 |
PA10H1 |
2T-FT
|
RLC072C
|
8
x 12 |
9000 |
A15H1 |
W10H1 |
PA15H1 |
2T-FT
|
RLC090C
|
8
x 14 |
12000 |
A15M1 |
W15H1 |
PA15M1 |
2T-FT
|
RLC135C
|
8
x 16 |
13200 |
A20H1 |
W15M1 |
PA20H1 |
2T-FT
|
RLC135C
|
8
x 18 |
14400 |
A20H1 |
W20H1 |
PA20H1 |
2T-FT
|
RLC135C
|
8
x 20 |
15600 |
A20H1 |
W20H1 |
PA20H1 |
2T-FT
|
RLC160C
|
8
x 22 |
16800 |
A20M1 |
W20H1 |
PA20M1 |
2T-FT
|
RLC160C
|
8
x 24 |
18000 |
A30H1 |
W20M1 |
PA30H1 |
2T-FT
|
RLC130C
|
8
x 26 |
19200 |
A30H1 |
W20M1 |
PA30H1 |
2T-FT
|
RLC200C
|
10
x 10 |
9500 |
A15H1 |
W10H1 |
PA15H1 |
2T-FT
|
RLC090C
|
10
x 12 |
11100 |
A15H1 |
W10M1 |
PA15H1 |
2T-FT
|
RLC105C
|
10
x 14 |
12700 |
A15M1 |
W15M1 |
PA15M1 |
2T-FT
|
RLC135C
|
10
x 16 |
14300 |
A20H1 |
W20H1 |
PA20H1 |
2T-FT
|
RLC135C
|
10
x 18 |
15900 |
A20H1 |
W20H1 |
PA20H1 |
2T-FT
|
RLC160C
|
10
x 20 |
17500 |
A30H1 |
W20H1 |
PA30H1 |
2T-FT
|
RLC180C
|
10
x 22 |
19100 |
A30H1 |
W20M1 |
PA30H1 |
2T-FT
|
RLC200C
|
10
x 24 |
20700 |
A30H1 |
W30H1 |
PA30H1 |
2T-FT
|
RLC200C
|
10
x 26 |
22300 |
A30H1 |
W30H1 |
PA30H1 |
2T-FT
|
(2)
RLC105C
|
12
x 12 |
13000 |
A20H1 |
W15M1 |
PA20H1 |
2T-FT
|
RLC135C
|
12
x 14 |
14400 |
A20H1 |
W20H1 |
PA20H1 |
2T-FT
|
RLC135C
|
12
x 16 |
16800 |
A20M1 |
W20H1 |
PA20M1 |
2T-FT
|
RLC160C
|
12
x 18 |
13200 |
A30H1 |
W20M1 |
PA30H1 |
2T-FT
|
RLC180C
|
12
x 20 |
19600 |
A30H1 |
W20M1 |
PA30H1 |
2T-FT
|
RLC200C
|
12
x 22 |
21000 |
A30H1 |
W30H1 |
PA20H1 |
2T-FT
|
RLC200C
|
12
x 24 |
22400 |
A30H1 |
W30H1 |
PA30H1 |
2T-FT
|
RLC200C
|
12
x 26 |
23800 |
A30M1 |
W30H1 |
PA30M1 |
2T-FT
|
(2)
RLC105C
|
12
x 28 |
25200 |
A30M1 |
W30H1 |
PA30M1 |
2T-FT
|
(2)
RLC135C
|
12
x 30 |
26600 |
A50H1 |
W30H1 |
PA50H1 |
2T-FT
|
(2)
RLC135C
|
12
x 32 |
28000 |
A50H1 |
W30H1 |
PA50H1 |
2T-FT
|
(2)
RLC135C
|
12
x 34 |
29400 |
A50H1 |
W30H1 |
PA50H1 |
2T-FT
|
(2)
RLC135C
|
12
x 36 |
30800 |
A50H1 |
W30M1 |
PA50H1 |
2T-FT
|
(2)
RLC160C
|
12
x 38 |
32200 |
A50H1 |
W30M1 |
PA50H1 |
2T-FT
|
(2)
RLC160C
|
14
x 14 |
16900 |
A20M1 |
W20H1 |
PA20M1 |
2T-FT
|
RLC160C
|
14
x 16 |
18600 |
A30H1 |
W20M1 |
PA30H1 |
2T-FT
|
RLC180C
|
14
x 18 |
20300 |
A30H1 |
W30H1 |
PA30H1 |
2T-FT
|
RLC200C
|
14
x 20 |
22000 |
A30H1 |
W30H1 |
PA30H1 |
2T-FT
|
RLC200C
|
14
x 22 |
23700 |
A30H1 |
W30H1 |
PA30H1 |
2T-FT
|
RLC250C
|
14
x 24 |
25400 |
A30M1 |
W30H1 |
PA30M1 |
2T-FT
|
RLC250C
|
14
x 26 |
27100 |
A30M1 |
W30H1 |
PA30M1 |
2T-FT
|
(2)
RLC135C
|
14
x 28 |
28800 |
A50H1 |
W30H1 |
PA30M1 |
2T-FT
|
(2)
RLC135C
|
14
x 30 |
30500 |
A50H1 |
W30M1 |
PA50H1 |
2T-FT
|
(2)
RLC160C
|
14
x 32 |
32200 |
A50H1 |
W30M1 |
PA50H1 |
2T-FT
|
(2)
RLC160C
|
14
x 34 |
33900 |
A50H1 |
W30M1 |
PA50H1 |
2T-FT
|
(2)
RLC160C
|
14
x 36 |
35600 |
A50H1 |
W50H1 |
PA50H1 |
2T-FT
|
(2)
RLC160C
|
14
x 38 |
36300 |
A50H1 |
W50H1 |
PA50H1 |
2T-FT
|
(2)
RLC180C
|
|
Refrigeration
Requirements for Walk-In Freezer
|
NOTES:
1. Air-Cooled capacities are at 90°F ambient temperature
with 60°F suction gas temperature and 0°F liquid subcooling.
All units are based on approximately 20°F.T.D.
2. Water-Cooled capacities are at 85°F entering water
temperature with 65°F suction gas temperature and 0°F
liquid subcooling. All Units are based on approximately 15°
F.T.D. between the condensing temperature and the entering
water temperature.
3. Increase capacity 6% for wach 10°F lower water or air
temperature; decreasing capacity 6% for each 10°F higher
water or air temperature.
|
|