WALK-IN
FREEZER
Panels:
- -
8' Standard Height
- -
4" Thick polystyrene insulated cam lock wall panels
built to NSF standards
- -
White embossed metal in/out/aluminum/ galvanized
- -
UL approved door panel assembly
*
Includes: interior light prewired to exterior switch, digital
thermometer and lockable handle
Choice
of remote refrigeration system:
- Indoor:
Condensing unit with matching low silhouette evaporator
coil and temperature operated control package. R-404 Refrigerant
and required tubing by others.
- Outdoor:
(See Outdoor Model) Condensing unit with matching low silhouette
evaporated coil, pumpdown control package and weatherhood.
R-404 Refrigerant and required tubing by others.
|
|
Click
on Size O.D. FT to send us Request for Quote
SIZE
O.D. FT
|
BTU/HR
REQUIRED
|
REMOTE
REFRIGERATION SYSTEM
|
CONTROL
PANEL
MODEL #
|
COIL
MODEL #
|
INDOOR
UNIT
|
OUTDOOR
UNIT
|
AIR-COOLED
|
WATER-COOLED
|
AIR-COOLED
|
208-220/3/60
|
MCQUAY
|
8
x 8-F |
6850 |
A20L5 |
W20L5 |
PA20L5 |
2T-FS-3-C1 |
ELC070B |
8
x 10-F |
7750 |
A21L5 |
W21L5 |
PA21L5 |
2T-FS-3-C1 |
ELC070B |
8
x 12-F |
8800 |
A30L5 |
W30L5 |
PA30L5 |
2T-FS-3-C1 |
ELC105B |
8
X 14-F |
9850 |
A30L5 |
W30L5 |
PA30L5 |
2T-FS-3-C1 |
ELC105B |
8
x 16-F |
10700 |
A30L5 |
W30L5 |
PA30L5 |
2T-FS-3-C1 |
ELC105B |
8
x 18-F |
11700 |
A31L5 |
W31L5 |
PA31L5 |
2T-FS-3-C1 |
ELC105B |
8
x 20-F |
12800 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C1 |
ELC140B |
8
x 22-F |
13800 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C2 |
(2)
ELC070B |
8
x 24-F |
14800 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C2 |
(2)
ELC070B |
8
x 26-F |
15900 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C2 |
(2)
ELC070B |
10
x 10-F |
9050 |
A30L5 |
W30L5 |
PA30L5 |
2T-FS-3-C1 |
ELC105B |
10
x 12-F |
9900 |
A30L5 |
W30L5 |
PA30L5 |
2T-FS-3-C1 |
ELC105B |
10
x 14-F |
10900 |
A30L5 |
W30L5 |
PA30L5 |
2T-FS-3-C1 |
ELC105B |
10
x 16-F |
11900 |
A31L5 |
W31L5 |
PA31L5 |
2T-FS-3-C1 |
ELC105B |
10
x 18-F |
12900 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C1 |
ELC140B |
10
x 20-F |
13900 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C1 |
ELC140B |
10
x 22-F |
14900 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C2 |
(2)
ELC070B |
10
x 24-F |
15850 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C2 |
(2)
ELC070B |
10
x 26-F |
16800 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C2 |
(2)
ELC070B |
12
x 12-F |
11600 |
A31L5 |
W31L5 |
PA31L5 |
2T-FS-3-C1 |
ELC105B |
12
x 14-F |
12600 |
A31L5 |
W31L5 |
PA31L5 |
2T-FS-3-C1 |
ELC105B |
12
x 16-F |
13700 |
A31L5 |
W31L5 |
PA31L5 |
2T-FS-3-C1 |
ELC105B |
12
x 18-F |
14700 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C1 |
ELC140B |
12
x 20-F |
15500 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C1 |
ELC140B |
12
x 22-F |
16450 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C2 |
(2)
ELC070B |
12
x 24-F |
17300 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C2 |
(2)
ELC070B |
12
x 26-F |
18200 |
A51L5 |
W51L5 |
PA51L5 |
2T-FS-4-C2 |
(2)
ELC090B |
12
x 28-F |
19200 |
A51L5 |
W51L5 |
PA51L5 |
2T-FS-4-C2 |
(2)
ELC090B |
12
x 30-F |
20200 |
A51L5 |
W51L5 |
PA51L5 |
2T-FS-4-C2 |
(2)
ELC090B |
14
x 14-F |
13900 |
A31L5 |
W31L5 |
PA31L5 |
2T-FS-3-C1 |
ELC105B |
14
x 16-F |
15000 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-3-C1 |
ELC140B |
14
x 18-F |
16100 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-4-C1 |
ELC160B |
14
x 20-F |
17200 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-4-C1 |
ELC160B |
14
x 22-F |
18300 |
A51L5 |
W51L5 |
PA51L5 |
2T-FS-4-C2 |
(2)
ELC090B |
14
x 24-F |
19400 |
A51L5 |
W51L5 |
PA51L5 |
2T-FS-4-C2 |
(2)
ELC090B |
14
x 26-F |
20500 |
A51L5 |
W51L5 |
PA51L5 |
2T-FS-4-C2 |
(2)
ELC090B |
14
X 28-F |
21600 |
A75L5 |
W75L5 |
PA75L5 |
2T-FS-4-C2 |
(2)
ELC105B |
14
x 30-F |
22700 |
A75L5 |
W75L5 |
PA75L5 |
2T-FS-4-C2 |
(2)
ELC105B |
16
x 16-F |
16500 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-4-C1 |
ELC160B |
16
x 18-F |
17500 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-4-C1 |
ELC160B |
16
x 20-F |
18500 |
A50L5 |
W50L5 |
PA50L5 |
2T-FS-4-C1 |
ELC175B |
16
x 22-F |
19600 |
A51L5 |
W51L5 |
PA51L5 |
2T-FS-4-C2 |
(2)
ELC090B |
16
x 24-F |
20600 |
A51L5 |
W51L5 |
PA51L5 |
2T-FS-4-C2 |
(2)
ELC090B |
16
x 26-F |
21700 |
A75L5 |
W75L5 |
PA75L5 |
2T-FS-4-C2 |
(2)
ELC105B |
16
x 28-F |
22800 |
A75L5 |
W75L5 |
PA75L5 |
2T-FS-4-C2 |
(2)
ELC105B |
16
x 30-F |
24000 |
A76L5 |
W76L5 |
PA76L5 |
2T-FS-4-C2 |
(2)
ELC120B |
|
Refrigeration
Requirements for Walk-In Freezer
|
NOTES:
1. Air-Cooled capacities are at 90°F ambient temperature
with 60°F suction gas temperature and 0°F liquid subcooling.
All units are based on approximately 20°F.T.D.
2. Water-Cooled capacities are at 85°F entering water
temperature with 65°F suction gas temperature and 0°F
liquid subcooling. All Units are based on approximately 15°
F.T.D. between the condensing temperature and the entering
water temperature.
3. Increase capacity 6% for wach 10°F lower water or air
temperature; decreasing capacity 6% for each 10°F higher
water or air temperature.
|
|